At power ON the instrument can operate in two different mode according to the value assigned to [34] r.md parameter [34] r.md equal to 0, (Limit output is de-energized at power on in any cases.). 2. when you re-congure an instrument previously used for other works or from other people or when you have made too many errors during conguration and you decided to re-congure the instrument, it is possible to restore the factory conguration. The conguration procedure allows to take advantage of all instrument features. The UT35A/UT32A also support open networks such as Ethernet communication. Set detailed parameter out group o1.F (output 1 function) = r.inP. Search the full list . Moreover, provide indication that the. (24 VAC/DC), 6.0 VA max. 600W. a change of the parameters related with it (e.g. I want to use it as a display. , we recommend to congure the parameters to. condensation); 5. Notes: 1. The instrument will show a measured value up to 5% higher than [4] FSc value and then it will show, Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. and access the next parameter within the same group. The EU Declaration of Conformity and the manual of the controller. Yokogawa TC10 Manual Download for 1 TC10 TEMPERATURE CONTROLLER Engineering Manual Code: IM 05C01E81-02EN Third edition: Feb. 2018 Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns 1. Category: Controller. PDF Model TC10 Temperature Controller, Engineering Manual - Weschler On the TC10, what does it mean if AL and 1 are lit? use only, in an electrical panel which encloses the rear housing. that no power is being supplied to a cable to be connected. TC10 is a panel mounting, Class II instrument. Clamp meters can perform analyses in the field on live conductors without interrupting the circuit. AL on the front of the TC10 is the alarm lamp. Before connecting the output actuators, we recommend to congure the parameters to, Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. 2.56 in min. The equipment wholly protected by double insulation or, - Whenever a failure or a malfunction of the device may cause dan-, gerous situations for persons, things or animals, please remember, that the plant must be equipped with additional devices which, - We warrant that the products will be free from defects in material. I'm sending the temperature via PV transmission on TC10. Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. Installation altitude: less than 2000 m; The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. When the upper display is showing a parameter and, Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. 3 2.3 OUTPUTS Safety notes: - To avoid electrical shocks, connect power line at last. Looking for more information on our people, technology and solutions? The output relay is always de-energized (opened) at poweron,even if PV does not exceed SP(A). IP65 rated as "dust tight" and protected against water projected from a nozzle when the optional panel gasket is mounted (for indoor locations) according to EN 60070-1. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O, Upload manuals that we do not have and get. The TC10-L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user. Notes: 1. facilities, aviation facilities, and medical equipment. The UT35A and UT32A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. facilities, aviation facilities, and medical equipment. It has been designed with compliance to the European Directives. What settings should I use to output PV transmission from ananalog output terminal on TC10? Copyright 1994-2023 Yokogawa Corporation of America, {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Floating Production Storage & Offloading (FPSO), Special Solutions of OpreX Transformation, Terminal Logistics Suite VP (Terminal Automation), Visual MESA Supply Chain Scheduling (VM-SCS), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Mobile Field Device Management (FieldMate), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), OpreX Data Model Broker / Design Data Validation, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Distributed Fiber Optic Temperature Sensor, Industry and Interface Libraries (Applications and Interfaces), Yokogawa Pre-Engineered Analyzer Solutions - YES, Loading, Metering and Blending Automation, Plant Annunciator and SOE Recording System, Transmitterless SENCOMSMART Sensor Platform, Advanced Control Bioreactor System BR1000, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, TC10-L Temperature Controller Limit Control Type Engineering Manual, TC10-L Temperature Controller Limit Control Type Serial communicaiton protocol, TC10-L Temperature Controller (Limit Control Type), Model TC10-L Temperature Controller (Limit Control Type). To protect the AL2 and AL3 thresholds against, undesired changes, they are available only at "Parameters, list" level (password: 20). I selected SP value transmission on TC10, but no SP value is displayed. PDF TC 10 - L 1.3 MOUNTING REQUIREMENTS TC10 - Yokogawa Compliance: directive EMC 2004/108/CE (EN 61326-1), directive LV 2006/95/CE (EN 61010-1). : 500W. The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. YOKOGAWA TC 10-L Controller Manual PDF View/Download The following symbol is, This manual is an essential part of the product; keep it in a safe place for. RS-485 interface allows to connect up to 30 devices with one remote master unit. - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. The default data are those typical values loaded in the instrument prior to ship it from factory. countries or regions where wiring will be installed. Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), IP65 front panel (when the optional panel gasket is mounted)(optional), Power consumption: 4.5 VA max. - For control relay output, alarm relay output, and power terminal, L H C o R o D o F /GK Temperature Controller, NOTE about the structure of this document, The usual installation sequence is the reverse of the operator, During installation, the first step is the wiring procedure followed, by the complete configuration. -For supply connections use No. SSR outputs are not isolated. Main Features Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals) 3 Dynamic Colors Led Display Universal input: (TC, mV, V, mA, Pt100-Pt1000) 4 Set Points and alarm functions Serial communication : RS-485 Modbus PID control, ON/OFF, Auto-tuning The TC10 is a compact single loop temperature controller with an easy-to-read 3-color LED display. YOKOGAWA TC10-L Quick Manual; YOKOGAWA TC10-L Quick Manual. PDF ELECTRICAL CONNECTIONS Outputs TERMINALS - Yokogawa Input impedance:> 1 M. The short depth of the controller helps save instrument panel space. condensation); 5. Select a mounting location having the following characteristics: 2. Input impedance: > 1 MW for mV Input 500 kW for Volt Input. For supply connections use No. Case: Plastic, self-extinguishing degree: V-0 according to UL 94, Front protection: IP 65 (when the optional panel gasket is mounted) for indoor locations according to EN 60070-1, Terminals protection: IP 20 according to EN 60070-1, Terminal block: 16 screw terminals for cables of 0.25 to 2.5 mm2 (AWG22 to AWG14) with connection diagram, tightening torque 0.5 Nm, Dimensions: 48 x 48, depth 62 mm (1.89 x 1.89 x 2.87 in. This manual is intended for the following personnel: - Engineers responsible for installation, wiring, and maintenance of, - Personnel responsible for normal daily operation of the equip-, Calls attention to actions or conditions that could cause serious or, fatal injury to the user or damage to the instrument, and indicates, precautions that should be taken to prevent such occurrences. Limit control type. We assume no liability for safety, or responsibility for the, product's quality, performance or functionality should users fail to. TC10-L is capable of a retransmission output and up to two alarm outputs. The following symbol is, This manual is an essential part of the product; keep it in a safe place for. use only, in an electrical panel which encloses the rear housing. 1.Do not run input wires together with power cables. However, the instrument will only show the parameters applicable to its hardware options in accordance with the specic instrument conguration (i.e. the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN. period. Backed by the high reliability and quality that Yokogawa has cultivated over many years. Select a mounting location having the following characteristics: 2. OUTLINE DIMENSIONS (mm) 1.1 INSTRUMENT DIMENSIONS 48 PV Optional gasket 1.2 PANEL CUT-OUT 45 +0.6 mm 1.78 +0.023 External resistance: 100W max., maximum error 25 V. Cold junction: automatic compensation between 0 to 55C. 2.It is possible to set a initial scale read-out higher than the full scale read-out in order to obtain a reverse read-out scaling. Looking for more information on our people, technology and solutions? There are no water or other fluids (i.e. No. Sometime, e.g. Note: The resistance of the 3 wires must be the same. Note: The group selection is cyclic as well as the selection of the parameters in a group. Line resistance: Automatic compensation up to 20W/wire with maximum error 0.1% of the input span. All information about the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN and General Specification: GS 05C01E81-01EN. The. The Yokogawa TC10 is a compact, all-in-one, single loop temperature controller with an easy-to-read, 3-color LED display. Can it output the SP setting value? TC10 is a panel mounting, Class II instrument. It has been de-, signed with compliance to the European Directives. Yokogawa TC10-L Manual The instrument will turn OFF all LEDs for a few seconds, then the upper display will show dFLt (default) and then all LEDs are turned ON for 2 seconds. Safety, Protection, and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. condensation); 5.The ambient temperature is in accordance with the operative temperature (0 to 50C); 6.The relative humidity is in accordance with the instrument specications (20 to 90%); The instrument can be mounted on panel with a maximum thickness of 8 mm. Select a mounting location having the following characteristics: 2. Search the full list . It has been designed, with compliance to the European Directives. Use of the in-, strument in a manner not prescribed herein may compromise the, product's functions and the protection features inherent in the, device. All information about the controller use can be found in the Engineering Manual: - IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN and General Specification: GS 05C01E81-01EN. {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Floating Production Storage & Offloading (FPSO), Special Solutions of OpreX Transformation, Terminal Logistics Suite VP (Terminal Automation), Visual MESA Supply Chain Scheduling (VM-SCS), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Mobile Field Device Management (FieldMate), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), OpreX Data Model Broker / Design Data Validation, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Distributed Fiber Optic Temperature Sensor, Industry and Interface Libraries (Applications and Interfaces), Yokogawa Pre-Engineered Analyzer Solutions - YES, Loading, Metering and Blending Automation, Plant Annunciator and SOE Recording System, Transmitterless SENCOMSMART Sensor Platform, Advanced Control Bioreactor System BR1000, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, Support Information - New Legislative Framework (NLF) Conforming Products, Temperature Control for Seal-heating Parts in Wrapping Machinery. Pay attention to the line resistance; a high line resistance, Digital indicating controllers (476 pages), Program temperature controller (37 pages), Temperature measurement module (44 pages), Manual will be automatically added to "My Manuals", Keyboard Functions During Parameter Changing, Factory Reset - Default Parameters Loading Procedure, How to See but Not Modify "Limited Access Parameters", Keyboard Function When the Instrument Is in Auto Mode, Temperature Controller YOKOGAWA TC10 Quick Manual, Temperature Controller Yokogawa TC10 Quick Manual, Temperature Controller YOKOGAWA TC User Manual, Temperature Controller YOKOGAWA UT55A User Manual, Temperature Controller YOKOGAWA UP150 User Manual, Temperature Controller YOKOGAWA XS550 User Manual, Temperature Controller YOKOGAWA UT130 Technical Information, Temperature Controller YOKOGAWA UT150 User Manual, Temperature Controller YOKOGAWA UT100 Series User Manual. Note: For TC wiring use proper compensating cable preferable shielded. Use a tester or similar device to ensure. The shallow depth of the controller helps to save instrument panel space. Are the TC10s wiring terminals screw terminals? If this instrument is used in a manner not specified in this manual. 4.Pay attention to the line resistance; a high line resistance may cause measurement errors. IM 05C01E81-01EN 1 Edition Oct. 2014 st Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan internet site: www.yokogawa.com/ns Declaration of conformity and Manual retrieval TC10 is a panel mounting, Class II instrument. {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Special Solutions of OpreX Transformation, Visual MESA Supply Chain Scheduling (VM-SCS), Visual MESA Production Accounting (VM-PA), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), Digital Plant Operation Intelligence (DPI) Quality Stabilization System, OpreX Data Model Broker / Design Data Validation, OpreX Customer Service Management Software, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Single-Cell Analysis Solution Single Cellome, Distributed Temperature Sensor - Fire Detection/Fire Prevention -, Industry and Interface Libraries (Applications and Interfaces), Advanced Control Bioreactor System BR1000, ALH for FlowCam: Automated Liquid Handling, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, Support InformationNew Legislative Framework (NLF) Conforming Products, Temperature Control for Seal-heating Parts in Wrapping Machinery. Do I need a minus sign ( - ) on the alarm setting value? The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. Also, YOKOGAWA Electric Corporation assumes no liability for the customer's, failure to comply with these requirements. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O. The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. Supply Voltage: 100 to 240 VAC (-15 to +10%). IM 05C01E81-01EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, EU Declaration of conformity and Manual retrieval, TC10 is a panel mounting, Class II instrument. Yes, by changing the DP setting from 0 to 1. (63% response when the input changes from 10% 90%). YOKOGAWA TC10 TEMPERATURE CONTROLLER ENGINEERING MANUAL | ManualsLib TC10-L Limit Controller | Yokogawa Electric Corporation On the TC10, what does it mean if AL and 1 are lit? The ambient temperature is in accordance with the operative, 6. A ladder sequence function is included as standard. [4]FSc - Full scale read-out for linear input. 5.3 HOW TO ENTER THE CONFIGURATION MODES. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to . Yokogawa TC10-L Limit Controller | Temperature Controllers - Instrumart - As a safety measure, always install a circuit breaker (an IEC 60947, compatible product, 5 A, 100 V or 220 V AC) in an easily accessible, location near the instrument. The UT52A/MDL supports 920 MHz band wireless communication. Yes, if the input type is voltage or current. Wattmeter power consumption is the estimated hourly, energy consumption (using Load Voltage and Load Current, parameter values), computed on the previous 15 minutes. Note: Before starting the configuration code setting, please define and write down Cod1 and Cod2 as needed: Linear 0 to 20 mA (this selection forces Out 4 = TX), Linear 4 to 20 mA (this selection forces Out 4 = TX), Note: As default, when the alarms are active, only AL1 threshold, is available at "Operator Command" level to perform non, critical tasks. equipment and devices that ensure personnel safety. Set detailed parameter out group o1.F (output 1 function) = r.inP. 1. The shallow depth of the controller helps to save instrument panel space. YOKOGAWA TC10 QUICK MANUAL Pdf Download | ManualsLib The ambient temperature is in accordance with the, 6. connected to the low-voltage installation. Notes: 1. The Yokogawa TC10-L limit controller is an FM-approved limit controller that can be configured either as a high limit or as a low limit controller by a user. Copyright 1994-2023 Yokogawa Corporation of America. In the following pages we will describe all the parameters of the instrument. Note: The complete list of the default parameters is available in Appendix A. Allows to decrease the value of the selected parameter. The UT35A and UT32A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. The conguration parameters are collected in various groups. We assume no liability for safety, or responsibility for, the product's quality, performance or functionality should users.